RSF Supply is not an authorized distributor. We sell Preowned Surplus and Refurbished products, all warranties are with RSF Supply and not the manufacturer. Firmware or Software is not included.
Overview
Specs
Product ID and Maker | Brocade DS-6505B |
Fibre Channel Interfaces | Initially equipped with 12 ports capable of 16 Gb/s or 8 Gb/s, expandable to 24 ports with the Ports On Demand (POD) license; supports automatic speed adjustment for 4, 8, and 16 Gb/s |
Throughput Capability | Capable of 2.125 Gbps and 4.25 Gbps line speeds, both in full duplex mode (specific to 8 Gb switches) |
Buffer Memory | Dynamically allocated 8,192 frame buffers for every group of 24 ports |
Component Compatibility | Includes one power supply that is replaceable while operational, with an optional secondary power supply for redundancy; both have built-in fans |
Mounting Configuration | Compatible with 19-inch racks adhering to EIA 310 standards, provided by the user |
Total System Bandwidth | 384 Gb/s across all connections, supporting duplex operations |
Maximal Data Unit Size | Supports a frame payload up to 2,112 bytes |
Supported Traffic Types | Unicast data traffic is accommodated by the fabric switch architecture |
Administrative Interface Options | Features Connectrix Manager Converged Network Edition for remote monitoring, alongside 10/100 Mbps Ethernet (RJ-45), Fibre Channel, serial (RJ-45), and USB connectivity for management |
Physical Housing | Airflow from back to front (port side exhaust) with rear power entry; occupies 1U in rack height |
Dimensions (W x H x D) | 437.64 mm x 43.18 mm x 443.23 mm (17.23 in x 1.7 in x 17.45 in) |
Equipment Mass | 7.82 kg (17.25 lb) with a single power unit, excluding transceivers; 9.16 kg (20.19 lb) with two power units installed, also excluding transceivers |
Operational Temperature Range | From 0°C to 40°C (32°F to 104°F) during active use |
Storage Temperature Range | -25°C to 70°C (-13°F to 158°F) when not in operation |
Humidity Tolerance | 10% to 85% non-condensing at 40°C (104°F) when in use; 10% to 90%, non-condensing at 70°C (158°F) for storage |
Operating Altitude | Functional up to 3,000 meters (9,842 feet) above sea level |
Thermal Output | Generates 338 BTU/hr when all 24 ports are active |
Electrical Input Requirements | 85 V to 264 V, consuming 5 A to 2.5 A |
Frequency of Input | Designed for 47 Hz to 63 Hz |
Power Usage | Consumes 80 watts with all ports at 16 Gb/s populated; 60 watts with no transceivers installed |
Shock Resistance | Withstands 20 G for 6 ms in operational mode; 33 G for 11 ms when not operational |
DS-6505B
Orders typically ship within 1-3 Business days, if you need an item to ship sooner please contact us.
Product Description
The DS-6505B switch features 24x 16Gb SFP+ ports, with 12 active ports standard and the ability to upgrade to 24 via a POD license, supporting auto-sensing of 4, 8, and 16 Gb/s speeds. It delivers full line-speed switching with performance up to 4.25 Gbps line speed, full duplex, and has a substantial frame buffer capacity of 8,192 per 24-port group. For reliability, it includes a hot-swappable power supply and offers dual redundant options, supports an aggregate bandwidth of 384 Gb/s end-to-end full duplex, and ensures efficient management with options including 10/100 Mbps Ethernet and USB port access.Key Feature for the DS6505B
- What is the initial number of active ports on the DS-6505B switch, and how can it be expanded?
The DS-6505B switch initially comes with 12 active 16 Gb/s or 8 Gb/s ports, expandable to 24 ports using the Ports On Demand (POD) license. - How does the DS-6505B ensure optimal performance?
It provides full line-speed switching at 2.125 Gbps and 4.25 Gbps line speeds, full duplex, with a frame buffer of 8,192 per 24-port group, dynamically allocated. - Can the DS-6505B switch's components be replaced without shutting down?
Yes, the base switch includes a single, hot-swappable power supply with integrated cooling fans, and supports an optional dual redundant hot-swappable power supply. - What are the installation requirements for the DS-6505B switch?
It must be mounted in a 19-inch cabinet conforming to the EIA 310 standard. - What is the maximum aggregate bandwidth of the DS-6505B?
The maximum aggregate bandwidth is 384 Gb/s end-to-end, full duplex. - What is the maximum frame size supported by the DS-6505B switch?
The maximum frame size supported is a 2,112-byte payload. - What types of data traffic can the DS-6505B handle?
It supports fabric switches that handle unicast data traffic types. - How can the DS-6505B be managed and monitored?
Management access is available via Call-home integration with Connectrix Manager Converged Network Edition, 10/100 Mbps Ethernet (RJ-45), in-band over Fibre Channel, serial port (RJ-45), and one USB port. - What are the physical dimensions and weight of the DS-6505B switch?
The DS-6505B measures 437.64 mm in width, 43.18 mm in height, and 443.23 mm in depth, weighing 7.82 kg with one power supply and 9.16 kg with two power supplies, excluding transceivers. - What environmental conditions are required for the DS-6505B's operation?
It operates within a temperature range of 0°C to 40°C, with a relative humidity of 10% to 85% non-condensing at 40°C. For non-operating and storage, it withstands 10% to 90% relative humidity at 70°C and can be used at altitudes up to 3,000 meters.
Product Review
The Brocade DS-6505B offers flexible scalability with 12 out-of-the-box 16 Gb/s Fibre Channel ports, expandable to 24 ports, catering to varying network sizes and growth. While its auto-sensing ports and full line-speed switching capabilities ensure optimal performance, the switch's reliance on a Ports On Demand (POD) license for expansion could be seen as a limitation for immediate, cost-effective scalability. Additionally, the inclusion of a single hot-swappable power supply unit as standard, with the option for a redundant unit, strikes a balance between reliability and initial cost, but the necessity for an additional purchase to achieve redundancy could be a drawback for environments requiring high availability.
Overview
Specifications
Product ID and Maker | Brocade DS-6505B |
Fibre Channel Interfaces | Initially equipped with 12 ports capable of 16 Gb/s or 8 Gb/s, expandable to 24 ports with the Ports On Demand (POD) license; supports automatic speed adjustment for 4, 8, and 16 Gb/s |
Throughput Capability | Capable of 2.125 Gbps and 4.25 Gbps line speeds, both in full duplex mode (specific to 8 Gb switches) |
Buffer Memory | Dynamically allocated 8,192 frame buffers for every group of 24 ports |
Component Compatibility | Includes one power supply that is replaceable while operational, with an optional secondary power supply for redundancy; both have built-in fans |
Mounting Configuration | Compatible with 19-inch racks adhering to EIA 310 standards, provided by the user |
Total System Bandwidth | 384 Gb/s across all connections, supporting duplex operations |
Maximal Data Unit Size | Supports a frame payload up to 2,112 bytes |
Supported Traffic Types | Unicast data traffic is accommodated by the fabric switch architecture |
Administrative Interface Options | Features Connectrix Manager Converged Network Edition for remote monitoring, alongside 10/100 Mbps Ethernet (RJ-45), Fibre Channel, serial (RJ-45), and USB connectivity for management |
Physical Housing | Airflow from back to front (port side exhaust) with rear power entry; occupies 1U in rack height |
Dimensions (W x H x D) | 437.64 mm x 43.18 mm x 443.23 mm (17.23 in x 1.7 in x 17.45 in) |
Equipment Mass | 7.82 kg (17.25 lb) with a single power unit, excluding transceivers; 9.16 kg (20.19 lb) with two power units installed, also excluding transceivers |
Operational Temperature Range | From 0°C to 40°C (32°F to 104°F) during active use |
Storage Temperature Range | -25°C to 70°C (-13°F to 158°F) when not in operation |
Humidity Tolerance | 10% to 85% non-condensing at 40°C (104°F) when in use; 10% to 90%, non-condensing at 70°C (158°F) for storage |
Operating Altitude | Functional up to 3,000 meters (9,842 feet) above sea level |
Thermal Output | Generates 338 BTU/hr when all 24 ports are active |
Electrical Input Requirements | 85 V to 264 V, consuming 5 A to 2.5 A |
Frequency of Input | Designed for 47 Hz to 63 Hz |
Power Usage | Consumes 80 watts with all ports at 16 Gb/s populated; 60 watts with no transceivers installed |
Shock Resistance | Withstands 20 G for 6 ms in operational mode; 33 G for 11 ms when not operational |