Item Number and Maker | Arista DCS-7324X-BND-F |
Included Components | 7304 Chassis, Two 3kW Power Supplies, Four 7324X Fabric/Fan Modules, One Supervisor (Front-Rear) |
Redundancy Level | Graceful Performance Reduction |
Height | 11.80 inches (30 cm) |
Width | 3.70 inches (9.4 cm) |
Depth | 10.27 inches (26.1 cm) |
Weight | 11.6 pounds (5.3 kg) |
Power Usage (Typical/Max) | 191W / 288W |
Chassis Compatibility | DCS-7304 |
Operating Temperature Range | 0°C (32°F) to 40°C (104°F) |
Storage Temperature Range | -25°C (-13°F) to 70°C (158°F) |
Operating Humidity Range | 5% to 95% |
Altitude for Operation | 0 to 10,000 feet (0 to 3,000 meters) |
EMC Emissions Compliance | FCC, EN55032, EN61000-3-2, EN61000-3-3 |
Immunity Standards | EN55024, EN55035, EN300 386 |
Rack Space Requirement | 8 rack units |
Fabric Integration | Embedded within fabric cards |
Connectivity | Fully linked |
DCS-7324X-BND-F
Orders typically ship within 1-3 Business days, if you need an item to ship sooner please contact us.
Product Description
The DCS-7324X-BND-F Arista features a 7304 chassis, equipped with 2x3kW power supplies, 4x 7324X fabrics/fans, and one supervisor module with graceful degradation for redundancy. It has a compact form factor with dimensions of H: 11.80” (30cm), W: 3.70” (9.4 cm), D: 10.27” (26.1cm), and weighs 11.6 lbs (5.3 kg). Supporting a typical power consumption of 191W (maximum 288W), it operates effectively within a temperature range of 0°C to 40°C, at altitudes up to 10,000 ft (3,000m), and fits into 8 rack units, ensuring compliance with various EMC emissions and immunity standards.Key Feature for the DCS-7324X-BND-F
- What components are included with the DCS-7304 chassis package?
The package includes a 7304 chassis, 2x3kW power supplies, 4x 7324X Fabric/fans, and 1x Supervisor (F-R) with Graceful Degradation redundancy. - How is redundancy achieved in the DCS-7304 chassis?
Redundancy is achieved through Graceful Degradation, ensuring continuous operation even if a component fails. - Can you detail the physical dimensions and weight of the DCS-7304 chassis?
The chassis measures 11.80” (30cm) in height, 3.70” (9.4 cm) in width, and 10.27” (26.1cm) in depth, weighing 11.6 lbs (5.3 kg). - What is the typical and maximum power consumption of the DCS-7304 chassis?
Typical power consumption is 191W, with a maximum of 288W. - What are the operating and storage temperature ranges for the DCS-7304?
Operating temperature ranges from 0 °C (32°F) to 40°C (104°F), and storage temperature ranges from -25°C (-13°F) to 70°C (158°F). - What are the humidity requirements for the DCS-7304 chassis's operation?
The chassis requires a minimum relative humidity of 5% and a maximum of 95% for proper operation. - How many rack units does the DCS-7304 chassis occupy?
It fits into 8 rack units. - What are the EMC emissions and immunity standards met by the DCS-7304 chassis?
EMC Emissions: FCC, EN55032, EN61000-3-2, EN61000-3-3. Immunity: EN55024, EN55035, EN300 386. - What is the maximum operating altitude for the DCS-7304 chassis?
The maximum operating altitude is 10,000 ft (3,000m). - How does the DCS-7304 support integration and interconnectivity within its components?
Integration and interconnectivity are fully supported through the integrated fabric cards, ensuring seamless operation and communication between components.
Product Review
The Arista DCS-7324X-BND-F offers high performance and scalability, supported by its 7324X fabrics/fans and a supervisor for efficient network management. However, its operating temperature range is limited to 0°C to 40°C, potentially restricting deployment in environments with extreme temperatures. Additionally, the system's compact size and weight (11.6 lbs) make it suitable for space-constrained installations, but its power consumption (191W typical, 288W maximum) may be a consideration for energy-sensitive deployments.
Overview
Specifications
Item Number and Maker | Arista DCS-7324X-BND-F |
Included Components | 7304 Chassis, Two 3kW Power Supplies, Four 7324X Fabric/Fan Modules, One Supervisor (Front-Rear) |
Redundancy Level | Graceful Performance Reduction |
Height | 11.80 inches (30 cm) |
Width | 3.70 inches (9.4 cm) |
Depth | 10.27 inches (26.1 cm) |
Weight | 11.6 pounds (5.3 kg) |
Power Usage (Typical/Max) | 191W / 288W |
Chassis Compatibility | DCS-7304 |
Operating Temperature Range | 0°C (32°F) to 40°C (104°F) |
Storage Temperature Range | -25°C (-13°F) to 70°C (158°F) |
Operating Humidity Range | 5% to 95% |
Altitude for Operation | 0 to 10,000 feet (0 to 3,000 meters) |
EMC Emissions Compliance | FCC, EN55032, EN61000-3-2, EN61000-3-3 |
Immunity Standards | EN55024, EN55035, EN300 386 |
Rack Space Requirement | 8 rack units |
Fabric Integration | Embedded within fabric cards |
Connectivity | Fully linked |