RSF Supply is not an authorized distributor. We sell Preowned Surplus and Refurbished products, all warranties are with RSF Supply and not the manufacturer. Firmware or Software is not included.
Overview
- Operating temperature range from -40ºF to 140ºF (-40 to +60ºC) with a type test for 100 hours at 85ºC, indicating its reliability in extreme conditions.
- Shock and vibration resistance with a 30G impact at 11 ms, demonstrating its durability.
- Capability to operate at altitudes up to 10,000 ft (3,048 m), ensuring performance in various geographical locations.
Specs
Item Number | Cisco CGR2010SECK9 |
Manufacturer | Cisco |
PSU 1 AC Voltage | Nominal: 100-240 VAC, Operating: 85-264 VAC, DC Acceptance: 88-300 VDC |
PSU 2 DC Voltage | Nominal: 24-60 VDC, Operating: 20-75 VDC |
Minimum Frequency | 47 Hz |
Maximum Frequency | 63 Hz |
AC Current (Max) | 2 A |
AC Surge Current | 50 A |
DC Voltage Range | 24-60 VDC, with extension to 88-300 VDC |
Power Usage (No Modules) | 30 Watts |
Height | 3.5 in. (88.9 mm) |
Width | 17.25 in. (438.2 mm) |
Depth | 15 in. (381 mm) |
Rack Compatibility | 19 in. (48.3 cm) EIA Standard |
Mounting Option | Wall-Mount Capable |
Weight (1 PSU, No Modules) | 19 lbs (8.6 kg) |
Max Configured Weight | 25 lbs (11.4 kg) with 2 PSUs, 4 GRWICs |
Operational Temperature Range | -40ºF to 140ºF (-40ºC to +60ºC) Continuous, -40ºF to 185ºF (-40ºC to +85ºC) for 100 hrs |
Shock Resistance | 30G for 11 ms |
Maximum Operating Altitude | 10,000 ft (3,048 m) |
Non-operational Temperature | -40ºF to 185ºF (-40ºC to +85ºC) |
Non-operational Humidity | 5% to 95% non-condensing |
Non-operational Altitude | 16,000 ft (4,876 m) |
Non-operational Drop Test | 4 in. (100 mm) per ENG-339611 |
Seismic Resistance | NEBS GR-63 (5.4.1) |
CGR2010SECK9
Orders typically ship within 1-3 Business days, if you need an item to ship sooner please contact us.
Product Description
The CGR2010SECK9 Cisco features a dual power supply with an AC input voltage operating range of 85 - 264 VAC and accepts DC input with a range of 20 - 75 VDC, extendable to 88 - 300 VDC on a separate unit. Designed for versatility, it supports a system power consumption of 30 Watts with dimensions of 3.5 in. (H) x 17.25 in. (W) x 15 in. (D), and offers both rack-mount and wall-mount options. It operates within a temperature range of -40ºF to 140ºF and withstands conditions up to 10,000 ft altitude, ensuring reliability in diverse environments.FAQs for the CGR2010SECK9
- What is the nominal AC input voltage range for Power Supply Unit 1?
The nominal AC input voltage range for Power Supply Unit 1 is 100 - 240 VAC. - What are the dimensions of the device?
The device dimensions are 3.5 in. (H) x 17.25 in. (W) x 15 in. (D). - Can the AC power supply accept DC input, and what is its operating range?
Yes, the AC power supply can accept a DC input with an operating range of 88 - 300 VDC. - What is the weight of the device when fully configured?
The typical weight when fully configured with 2 power supplies and 4 GRWICs is 25 lbs (11.4 kg). - What is the operating temperature range for continuous operation?
The continuous operating temperature range is -40 ºF to 140ºF (-40 to +60ºC). - How much power does the system consume with no modules installed?
The system consumes 30 Watts with no modules installed. - What is the maximum AC input current range for the AC power supply?
The maximum AC input current range for the AC power supply is 2 A. - Is wall-mounting an option for this device?
Yes, wall-mounting is an option for this device. - What is the shock and vibration specification for this device?
The shock and vibration specification is 30G @11 ms. - What are the non-operating conditions related to altitude?
Under non-operating conditions, the device can withstand altitudes up to 16,000 ft (4,876 m).
Product Review
The Cisco CGR2010SECK9 offers flexible power input options, accepting both AC and DC power with a broad operating range, making it suitable for various deployment scenarios. Its compact design, capable of both rack-mount and wall-mount installations, along with a wide operating temperature range, ensures reliability in diverse environments. However, its system power consumption of 30 Watts without modules may be a consideration for energy-conscious deployments.
Overview
- Operating temperature range from -40ºF to 140ºF (-40 to +60ºC) with a type test for 100 hours at 85ºC, indicating its reliability in extreme conditions.
- Shock and vibration resistance with a 30G impact at 11 ms, demonstrating its durability.
- Capability to operate at altitudes up to 10,000 ft (3,048 m), ensuring performance in various geographical locations.
Specifications
Item Number | Cisco CGR2010SECK9 |
Manufacturer | Cisco |
PSU 1 AC Voltage | Nominal: 100-240 VAC, Operating: 85-264 VAC, DC Acceptance: 88-300 VDC |
PSU 2 DC Voltage | Nominal: 24-60 VDC, Operating: 20-75 VDC |
Minimum Frequency | 47 Hz |
Maximum Frequency | 63 Hz |
AC Current (Max) | 2 A |
AC Surge Current | 50 A |
DC Voltage Range | 24-60 VDC, with extension to 88-300 VDC |
Power Usage (No Modules) | 30 Watts |
Height | 3.5 in. (88.9 mm) |
Width | 17.25 in. (438.2 mm) |
Depth | 15 in. (381 mm) |
Rack Compatibility | 19 in. (48.3 cm) EIA Standard |
Mounting Option | Wall-Mount Capable |
Weight (1 PSU, No Modules) | 19 lbs (8.6 kg) |
Max Configured Weight | 25 lbs (11.4 kg) with 2 PSUs, 4 GRWICs |
Operational Temperature Range | -40ºF to 140ºF (-40ºC to +60ºC) Continuous, -40ºF to 185ºF (-40ºC to +85ºC) for 100 hrs |
Shock Resistance | 30G for 11 ms |
Maximum Operating Altitude | 10,000 ft (3,048 m) |
Non-operational Temperature | -40ºF to 185ºF (-40ºC to +85ºC) |
Non-operational Humidity | 5% to 95% non-condensing |
Non-operational Altitude | 16,000 ft (4,876 m) |
Non-operational Drop Test | 4 in. (100 mm) per ENG-339611 |
Seismic Resistance | NEBS GR-63 (5.4.1) |