RSF Supply is not an authorized distributor. We sell Preowned Surplus and Refurbished products, all warranties are with RSF Supply and not the manufacturer. Firmware or Software is not included.
Overview
Specs
Part Number and Manufacturer | Cisco ME-FANTRAY-XL |
Port Status Indicators | Indicates link integrity, disabled ports, and port activity |
Power Status Indicator | Displays power input/output status |
Alarm Indicator | Shows alarm status |
SyncE Indicator | Displays SyncE status |
System Indicator | Shows overall system status |
Height | 3.5 inches (88.9 mm) - 2RU |
Width | 17.5 inches (444.5 mm) |
Depth | 15.5 inches (393.7 mm) |
Weight with FANTRAY-XL and Two AC Power Supplies | 25.5 pounds (11.6 kg) |
ME3600X-24CX-M MTBF | 227,840 hours |
DC Power Supply MTBF (48V) | 319,000 hours at 40ºC |
AC Power Supply MTBF (120V) | 328,000 hours at 40ºC |
AC Power Supply MTBF (230V) | 342,000 hours at 40ºC |
ME-FANTRAY MTBF | 2,177,000 hours at 12V and 40ºC |
ME-FANTRAY-XL MTBF | 2,298,000 hours at 12V and 40ºC |
Power Usage with AC and Fan Tray (Typical) | 176 Watts |
Power Usage (Maximum) | 278 Watts |
Heat Dissipation (Typical) | 600 BTUs/hour |
Heat Dissipation (Maximum) | 949 BTUs/hour |
AC Input Range | 100–240VAC, 50–60Hz |
DC Input Range | 18V to 32VDC, 36V to 72VDC |
Operating Conditions (Temperature and Altitude) | –40 to +65ºC, up to 6000 feet (1800m) |
Extended Altitude Operating Conditions | –40 to +55ºC, up to 13,000 feet (4000m) |
Single Fan Failure Operating Conditions | Operational up to 4 hours at –40 to +65ºC |
Humidity Range | 5% to 85%, noncondensing |
Acoustic Noise Levels | Maximum: 78 dBA Lwad at 27ºC, Typical: 55 dBA Lwad |
ME-FANTRAY-XL
Orders typically ship within 1-3 Business days, if you need an item to ship sooner please contact us.
Product Description
The ME-FANTRAY-XL is designed with comprehensive indicators including per-port status LEDs for link integrity, activity, and port status, along with LEDs for power, alarm, SyncE, and system status, ensuring clear visibility into operational states. It has a physical dimension of 3.5-in (88.9 mm) height, 17.5-in (444.5 mm) width, and 15.5-in (393.7 mm) depth, fitting into a 2RU space, and weighs 25.5 lb (11.6 kg) when combined with ME-3600X-24CX-M and two PWR-ME3KX-AC. The device supports a wide range of power inputs, including 100–240VAC, 50–60Hz for AC and 18V to 32VDC, 36V to 72VDC for DC, operates efficiently within a temperature range of –40 to +65ºC at altitudes up to 6000 feet (1800m), and has an MTBF of 2,298,000 hours for reliable long-term use.Key Feature for the ME-FANTRAY-XL
- What are the different types of status LEDs available on the ME-3600X-24CX-M?
The ME-3600X-24CX-M features several status LEDs, including per-port status for link integrity, port disabled, and activity, as well as LEDs for power input/output status, alarm status, SyncE status, and system status. - How much does the ME3600X-24CX-M with FANTRAY-XL and two PWR-ME3KX-AC weigh?
The combined weight of the ME3600X-24CX-M with FANTRAY-XL and two PWR-ME3KX-AC units is 25.5 lb (11.6 kg). - What are the dimensions of the ME-3600X-24CX-M?
The device measures 3.5 inches (88.9 mm) in height, 17.5 inches (444.5 mm) in width, and 15.5 inches (393.7 mm) in depth. - What is the MTBF (Mean Time Between Failures) for the PWR-ME3KX-AC power supply?
The MTBF for the PWR-ME3KX-AC power supply is 328,000 hours at 120V and 342,000 hours at 230V. - What is the typical and maximum power consumption for the ME-3600X-24CX-M with one AC and one fan tray?
Typical power consumption is 176W, and maximum power consumption is 278W. - How long can the ME-3600X-24CX-M operate with a single fan failure?
The device can operate for up to 4 hours with a single fan failure under normal operating temperatures. - What is the operating temperature and altitude range for the ME-3600X-24CX-M?
The operating temperature range is -40 to +65ºC up to 6000 feet and -40 to +55ºC up to 13,000 feet. - What are the MTBF statistics for the ME-FANTRAY-XL?
The MTBF for the ME-FANTRAY-XL is 2,298,000 hours at 12V input at 40ºC. - What is the acoustic noise level for the ME-3600X-24CX-M?
The maximum acoustic noise level is 78 dBA Lwad at 27ºC, with a typical noise level of 55 dBA Lwad. - What input voltages does the ME-3600X-24CX-M support?
It supports AC input voltages of 100–240VAC, 50–60Hz, and DC input voltages of 18V to 32VDC and 36V to 72VDC.
Product Review
The Cisco ME-FANTRAY-XL is equipped with comprehensive indicators for monitoring system health, including per-port status, power input/output, alarm, SyncE, and system status LEDs, facilitating effective network management. However, its dimensions and weight require considerable rack space and support infrastructure, potentially limiting deployment in environments with space constraints. With an impressive mean time between failures (MTBF) and operational efficiency across a wide range of temperatures and altitudes, it ensures reliability and durability in diverse operational conditions, albeit with notable power consumption and acoustic noise levels under maximum load.
Overview
Specifications
Part Number and Manufacturer | Cisco ME-FANTRAY-XL |
Port Status Indicators | Indicates link integrity, disabled ports, and port activity |
Power Status Indicator | Displays power input/output status |
Alarm Indicator | Shows alarm status |
SyncE Indicator | Displays SyncE status |
System Indicator | Shows overall system status |
Height | 3.5 inches (88.9 mm) - 2RU |
Width | 17.5 inches (444.5 mm) |
Depth | 15.5 inches (393.7 mm) |
Weight with FANTRAY-XL and Two AC Power Supplies | 25.5 pounds (11.6 kg) |
ME3600X-24CX-M MTBF | 227,840 hours |
DC Power Supply MTBF (48V) | 319,000 hours at 40ºC |
AC Power Supply MTBF (120V) | 328,000 hours at 40ºC |
AC Power Supply MTBF (230V) | 342,000 hours at 40ºC |
ME-FANTRAY MTBF | 2,177,000 hours at 12V and 40ºC |
ME-FANTRAY-XL MTBF | 2,298,000 hours at 12V and 40ºC |
Power Usage with AC and Fan Tray (Typical) | 176 Watts |
Power Usage (Maximum) | 278 Watts |
Heat Dissipation (Typical) | 600 BTUs/hour |
Heat Dissipation (Maximum) | 949 BTUs/hour |
AC Input Range | 100–240VAC, 50–60Hz |
DC Input Range | 18V to 32VDC, 36V to 72VDC |
Operating Conditions (Temperature and Altitude) | –40 to +65ºC, up to 6000 feet (1800m) |
Extended Altitude Operating Conditions | –40 to +55ºC, up to 13,000 feet (4000m) |
Single Fan Failure Operating Conditions | Operational up to 4 hours at –40 to +65ºC |
Humidity Range | 5% to 85%, noncondensing |
Acoustic Noise Levels | Maximum: 78 dBA Lwad at 27ºC, Typical: 55 dBA Lwad |