Overview
- Regulatory compliance is comprehensive, including CE Markings according to directives 2004/108/EC and 2006/95/EC.
- Safety certifications are extensive, covering UL 60950-1, CAN/CSA-C22.2 No. 60950-1, EN 60950-1, IEC 60950-1, AS/NZS 60950-1, and GB4943.
- EMC emissions standards are met across multiple regions, with certifications including 47CFR Part 15 (CFR 47) Class A, AS/NZS CISPR22 Class A, CISPR22 Class A, EN55022 Class A, ICES003 Class A, VCCI Class A, EN61000-3-2, EN61000-3-3, KN22 Class A, and CNS13438 Class A.
Specs
Part Number and Manufacturer | Cisco UCS-FAN-6248UP |
Operating Power at Full Load (48 Ports) | 400W |
Peak Power Output | 750W |
Minimum DC Input | -40VDC |
Maximum DC Input | 72VDC |
Input Current Peak | 25A |
Top Input Power | 1000W |
Efficiency at Half Load | 88% |
Efficiency at Full Load | 92% |
Compliant with RoHS | Yes |
Capability for Hot Swap | Yes |
Thermal Output | 75W |
Components Weight (2 Power Units, 1 Expansion Module, 2 Fans) | 35 lb (15.88 kg) |
Regulatory Adherence | Meets CE Markings per 2004/108/EC and 2006/95/EC directives |
Standards for Safety | UL 60950-1, CAN/CSA-C22.2 No. 60950-1, EN 60950-1, IEC 60950-1, AS/NZS 60950-1, GB4943 |
EMC: Class A Emissions | 47CFR Part 15, AS/NZS CISPR22, CISPR22, EN55022, ICES003, VCCI, EN61000-3-2, EN61000-3-3, KN22, CNS13438 |
UCS-FAN-6248UP
Orders typically ship within 1-3 Business days, if you need an item to ship sooner please contact us.
Product Description
The Cisco UCS 6248UP operates with a typical power consumption of 400W across 48 ports and supports a maximum output power of 750W. It is designed for efficiency, achieving a minimum of 88% at 50% load and up to 92% efficiency at full load, with hot-swappable capabilities for seamless maintenance. This unit meets rigorous safety and regulatory standards, including UL 60950-1 and CE Markings, and is compliant with multiple EMC emissions classifications, ensuring broad compatibility and safe operation within diverse networking environments.Key Feature for the UCS-FAN-6248UP
- What is the typical operating power of the Cisco UCS 6248UP with all 48 ports active?
The typical operating power is 400W when all 48 ports are running at 100%. - How does the Cisco UCS 6248UP comply with RoHS standards?
Yes, it is RoHS compliant, ensuring it adheres to restrictions on hazardous substances. - What is the minimum input voltage required for the Cisco UCS 6248UP?
The minimum input voltage is -40VDC. - Is the Cisco UCS 6248UP hot swappable?
Yes, it features hot swappable components for easy maintenance without system downtime. - What is the maximum efficiency of the Cisco UCS 6248UP at full load?
At 100% load, the maximum efficiency reaches 92%. - How much heat does the Cisco UCS 6248UP dissipate at maximum output power?
It dissipates 75W of heat, which is 10% of its 750W maximum output power. - What are the safety certifications of the Cisco UCS 6248UP?
It is certified under UL 60950-1, CAN/CSA-C22.2 No. 60950-1, EN 60950-1, IEC 60950-1, AS/NZS 60950-1, and GB4943 standards. - Can the Cisco UCS 6248UP's power supply handle a maximum input of 1000W?
Yes, it can handle a maximum input power of 1000W with a maximum input current of 25A. - What is the weight of the Cisco UCS 6248UP with two power supplies, one expansion module, and two fan modules?
The weight is 35 lb (15.88 kg). - Does the Cisco UCS 6248UP meet EMC emissions standards?
Yes, it meets multiple EMC emissions standards, including 47CFR Part 15 (CFR 47) Class A, AS/NZS CISPR22 Class A, and others, ensuring reduced electromagnetic interference.
Product Review
The Cisco UCS-FAN-6248UP offers excellent energy efficiency, operating between 88% and 92% efficiency under loads ranging from 50% to 100%, which is beneficial for reducing operational costs in data centers. However, the unit requires a significant power input of up to 1000W and a minimum input voltage of -40VDC, necessitating robust power supply and management solutions. It meets a wide range of regulatory compliance standards, including EMC emissions and safety, ensuring its compatibility and safe operation in diverse environments, but its weight of 35 lb (15.88 kg) may pose challenges for installation and mobility within tight spaces.
Overview
- Regulatory compliance is comprehensive, including CE Markings according to directives 2004/108/EC and 2006/95/EC.
- Safety certifications are extensive, covering UL 60950-1, CAN/CSA-C22.2 No. 60950-1, EN 60950-1, IEC 60950-1, AS/NZS 60950-1, and GB4943.
- EMC emissions standards are met across multiple regions, with certifications including 47CFR Part 15 (CFR 47) Class A, AS/NZS CISPR22 Class A, CISPR22 Class A, EN55022 Class A, ICES003 Class A, VCCI Class A, EN61000-3-2, EN61000-3-3, KN22 Class A, and CNS13438 Class A.
Specifications
Part Number and Manufacturer | Cisco UCS-FAN-6248UP |
Operating Power at Full Load (48 Ports) | 400W |
Peak Power Output | 750W |
Minimum DC Input | -40VDC |
Maximum DC Input | 72VDC |
Input Current Peak | 25A |
Top Input Power | 1000W |
Efficiency at Half Load | 88% |
Efficiency at Full Load | 92% |
Compliant with RoHS | Yes |
Capability for Hot Swap | Yes |
Thermal Output | 75W |
Components Weight (2 Power Units, 1 Expansion Module, 2 Fans) | 35 lb (15.88 kg) |
Regulatory Adherence | Meets CE Markings per 2004/108/EC and 2006/95/EC directives |
Standards for Safety | UL 60950-1, CAN/CSA-C22.2 No. 60950-1, EN 60950-1, IEC 60950-1, AS/NZS 60950-1, GB4943 |
EMC: Class A Emissions | 47CFR Part 15, AS/NZS CISPR22, CISPR22, EN55022, ICES003, VCCI, EN61000-3-2, EN61000-3-3, KN22, CNS13438 |