RSF Supply is not an authorized distributor. We sell Preowned Surplus and Refurbished products, all warranties are with RSF Supply and not the manufacturer. Firmware or Software is not included.
Overview
- Power supply input receptacles are standardized with the International Electrotechnical Commission (IEC) 320-C20, ensuring broad compatibility.
- The power cord is rated for 16A, aligning with the unit's high-power capabilities.
- British thermal units (BTUs) vary with output, reaching up to 10,410 BTU/hour at 3051W output and 5292 BTU/hour at 1551W output, reflecting its efficiency and thermal management.
Specs
Part Number and Manufacturer | Cisco C6880X3KWAC |
Height | 1.6 inches (4.1 cm) |
Width | 3.95 inches (10 cm) |
Depth | 22 inches (55.9 cm) |
Mass | 5 pounds (2.27 kg) |
Minimum Input Voltage | 85 VAC |
Maximum Input Voltage | 264 VAC |
Minimum Input Frequency | 47 Hz |
Input Current per Input | Up to 20 A at standard voltage (110 or 220 VAC) |
Inrush Current | No more than 55 A for a single cycle |
Power Input Connectors | IEC 320-C20 |
Power Cord Capacity | 16A |
Heat Dissipation (3051W output) | 10,410 BTU per hour |
Heat Dissipation (1551W output) | 5292 BTU per hour |
Minimum Output Holdup Time | 20 ms |
Minimum Operating Temperature | 32 °F (0 °C) |
Maximum Operating Temperature | 104 °F (40 °C) |
Minimum Storage Temperature | -40 °F (-40 °C) |
Maximum Storage Temperature | 185 °F (85 °C) |
Operational Minimum Relative Humidity (Non-Condensing) | 10% |
Operational Maximum Relative Humidity (Non-Condensing) | 90% |
Non-Operational Minimum Relative Humidity (Non-Condensing) | 10% |
Non-Operational Maximum Relative Humidity (Non-Condensing) | 95% |
C6880X3KWAC
Orders typically ship within 1-3 Business days, if you need an item to ship sooner please contact us.
Product Description
The C6880X3KWAC Cisco has physical dimensions of 1.6 in. (4.1 cm) H, 3.95 in. (10 cm) W, and 22 in. (55.9 cm) D, with a weight of 5 lb (2.27 kg). It operates within an input voltage range of 85 VAC to 264 VAC, an input frequency range of 47 Hz to 63 Hz, and supports a maximum input current of 20 A at nominal line voltage. The device is designed to work in temperatures ranging from 32 °F (0 °C) to 104°F (40°C) with an operational humidity range of 10% to 90% noncondensing, ensuring reliable performance across various environmental conditions.Key Feature for the C6880X3KWAC
- What are the physical dimensions of the networking hardware?
The hardware measures 1.6 in. (4.1 cm) in height, 3.95 in. (10 cm) in width, and 22 in. (55.9 cm) in depth. - How much does the device weigh?
It weighs 5 lb (2.27 kg). - What is the input voltage range for the device?
The minimum input voltage is 85 VAC, and the maximum is 264 VAC. - What is the maximum input current?
The maximum input current at nominal line voltage (110 or 220 VAC) is 20 A. - Can you detail the power supply specifications?
The device uses IEC 320-C20 receptacles for its power supply, with a power cord rating of 16A. The rush-in current is a maximum of 55 A for one cycle. - What are the BTU ratings for the hardware?
At 3051W output, it produces 10,410 BTU/hour, and at 1551W output, it produces 5292 BTU/hour. - What is the output holdup time of the device?
The output holdup time is a minimum of 20 milliseconds (ms). - What are the operating temperature limits?
The minimum operating temperature is 32 °F (0 °C), and the maximum is 104°F (40°C). - What are the storage temperature ranges?
The device can be stored at temperatures ranging from –40 °F (–40°C) to 185°F (85°C). - Could you provide details on the device's humidity tolerance?
For operating conditions, it handles 10% to 90% noncondensing humidity. For non-operating conditions, it can withstand 10% to 95% noncondensing humidity.
Product Review
The Cisco C6880X3KWAC power supply unit offers a compact form factor with dimensions of 1.6 in. (H) x 3.95 in. (W) x 22 in. (D) and a weight of 5 lb, making it suitable for dense setups where space efficiency is crucial. It supports a wide range of input voltages (85-264 VAC) and frequencies (47-63 Hz), ensuring compatibility across various power sources and regions, but has a relatively high rush-in current of 55 A, which could necessitate careful planning in electrical infrastructure to avoid circuit breaker trips. The power supply operates efficiently within a broad temperature range (32°F to 104°F) and humidity (10% to 90% noncondensing), though its BTU output at full load (10,410 BTU/hour) may require adequate cooling solutions to manage heat within the network enclosure.
Overview
- Power supply input receptacles are standardized with the International Electrotechnical Commission (IEC) 320-C20, ensuring broad compatibility.
- The power cord is rated for 16A, aligning with the unit's high-power capabilities.
- British thermal units (BTUs) vary with output, reaching up to 10,410 BTU/hour at 3051W output and 5292 BTU/hour at 1551W output, reflecting its efficiency and thermal management.
Specifications
Part Number and Manufacturer | Cisco C6880X3KWAC |
Height | 1.6 inches (4.1 cm) |
Width | 3.95 inches (10 cm) |
Depth | 22 inches (55.9 cm) |
Mass | 5 pounds (2.27 kg) |
Minimum Input Voltage | 85 VAC |
Maximum Input Voltage | 264 VAC |
Minimum Input Frequency | 47 Hz |
Input Current per Input | Up to 20 A at standard voltage (110 or 220 VAC) |
Inrush Current | No more than 55 A for a single cycle |
Power Input Connectors | IEC 320-C20 |
Power Cord Capacity | 16A |
Heat Dissipation (3051W output) | 10,410 BTU per hour |
Heat Dissipation (1551W output) | 5292 BTU per hour |
Minimum Output Holdup Time | 20 ms |
Minimum Operating Temperature | 32 °F (0 °C) |
Maximum Operating Temperature | 104 °F (40 °C) |
Minimum Storage Temperature | -40 °F (-40 °C) |
Maximum Storage Temperature | 185 °F (85 °C) |
Operational Minimum Relative Humidity (Non-Condensing) | 10% |
Operational Maximum Relative Humidity (Non-Condensing) | 90% |
Non-Operational Minimum Relative Humidity (Non-Condensing) | 10% |
Non-Operational Maximum Relative Humidity (Non-Condensing) | 95% |