RSF Supply is not an authorized distributor. We sell Preowned Surplus and Refurbished products, all warranties are with RSF Supply and not the manufacturer. Firmware or Software is not included.
Overview
Specs
Part Number | N7K-DC-6.0KW |
Manufacturer | Cisco |
Power Output | 6.0 kW |
Environment | DC |
Power Range | 1500 W - 6000 W |
Hot-Swap Capability | Supported |
Input Count | 4 |
Includes Power Cable | Yes |
Connection Method | Direct to DC sources & via Power Interface Unit |
Efficiency Rating | Over 91% |
Designed For | Nexus 7000 Series |
AC/DC Operation | Supported |
Securing Mechanism | Integrated Latch |
Power Cable Measure | 15 feet |
Cable Standard | GR-347 |
Securing Torque Range | 15-40 in-lb |
Input Stage Connections | Two -48 VDC |
Software Requirement | NX-OS 5.0+ |
Holdup Time (50% Load) | 8 ms |
Holdup Time (100% Load) | 4 ms |
Dimensions | 8.51 x 4 x 21.25 inches |
Mass | 21 pounds |
Grounding Type | Dual Stud at Front |
DC Voltage Input | -48 VDC at 37 A / -60 VDC at 30 A (NA) |
Input Current per DC Input | 40A at -48 VDC |
Operating Temperature Range | 0 °C to 40 °C |
Humidity Tolerance | 10% to 90% Non-condensing |
N7K-DC-6.0KW
Orders typically ship within 1-3 Business days, if you need an item to ship sooner please contact us.
Product Description
The N7K-DC-6.0KW is a 6.0 KW power supply unit designed specifically for DC environments, compatible with Cisco Nexus 7000 Series Switches. It offers scalability from 1500 W to 6000 W, supports hot swapping, and provides an efficiency of more than 91%. This unit features a -48 VDC nominal input voltage at 37 A for North America, supports mixed DC and AC operation, and is designed for direct connection to DC power sources or through an intermediate power interface unit, ensuring reliable power delivery and system operation.Key Feature for the N7K-DC-6.0KW
- What is the power rating of this networking hardware?
The power rating is 6.0 KW. - Is the device compatible with Cisco Nexus 7000 Series Switches?
Yes, it is compatible with Cisco Nexus 7000 Series Switches. - Can the power supply support hot swapping?
Yes, it supports hot swapping. - What is the efficiency rating of the power supply?
The efficiency is more than 91%. - How many power inputs does the device have?
There are 4 power inputs. - Does the power supply allow for mixed DC and AC operation?
Yes, it supports mixed DC and AC operation. - What is the minimum and maximum tightening torque for connections?
The minimum is 15 in. per lb and the maximum is 40 in. per lb. - What software version is required for compatibility?
Cisco® NX-OS Software Release 5.0 or later is required for compatibility. - What are the dimensions of the power supply?
The dimensions are 8.51 x 4 x 21.25 inches (H x W x D). - What type of power cable is included with the device?
A 15 ft. power cable rated GR-347 is included.
Product Review
The Cisco N7K-DC-6.0KW power supply module offers high efficiency of over 91%, ensuring reduced energy wastage and cost savings in data center environments. Its scalability from 1500 W to 6000 W and hot swap support enable seamless power adjustments and maintenance without system downtime, enhancing operational flexibility. However, its operation limited to a temperature range of 0 °C to 40 °C may restrict its deployment in environments with extreme temperature conditions.
Overview
Specifications
Part Number | N7K-DC-6.0KW |
Manufacturer | Cisco |
Power Output | 6.0 kW |
Environment | DC |
Power Range | 1500 W - 6000 W |
Hot-Swap Capability | Supported |
Input Count | 4 |
Includes Power Cable | Yes |
Connection Method | Direct to DC sources & via Power Interface Unit |
Efficiency Rating | Over 91% |
Designed For | Nexus 7000 Series |
AC/DC Operation | Supported |
Securing Mechanism | Integrated Latch |
Power Cable Measure | 15 feet |
Cable Standard | GR-347 |
Securing Torque Range | 15-40 in-lb |
Input Stage Connections | Two -48 VDC |
Software Requirement | NX-OS 5.0+ |
Holdup Time (50% Load) | 8 ms |
Holdup Time (100% Load) | 4 ms |
Dimensions | 8.51 x 4 x 21.25 inches |
Mass | 21 pounds |
Grounding Type | Dual Stud at Front |
DC Voltage Input | -48 VDC at 37 A / -60 VDC at 30 A (NA) |
Input Current per DC Input | 40A at -48 VDC |
Operating Temperature Range | 0 °C to 40 °C |
Humidity Tolerance | 10% to 90% Non-condensing |