RSF Supply is not an authorized distributor. We sell Preowned Surplus and Refurbished products, all warranties are with RSF Supply and not the manufacturer. Firmware or Software is not included.
Overview
- Ring frequency options of 20, 25, 30, and 50 Hz,
- Support for both Category 3 and Category 5 cables,
- Operation within a voltage of 12 V from the backplane and a current of 5.86 A on 12V, resulting in a power consumption of 70.32 W.
Specs
Part Number | Cisco SM-X-16FXS/2FXO |
Manufacturer | Cisco |
FXS Port Count | 16 |
FXO Port Count | 2 |
FXO Bypass for Failover | 2 |
Enabled FXS-E Ports | 16 |
Compatible with ISR 4000 Series | 4331, 4351, 4451 |
Supported Address Signaling | In-Band DTMF, Out-of-Band Pulse (8-12 pps) |
FXS Signaling Supported | Loop-Start, Ground-Start, DID |
Resistance for FXS Loop | Up to 600 Ohms (Short), Up to 1400 Ohms (Long) |
DID Loop Resistance | Maximum 1800 Ohms |
Voltage when On-Hook | -44 V |
Loop Current Off-Hook | 25 mA (Short), 35 mA (Long) |
Ring Signal Frequency | 20, 25, 30, 50 Hz |
Maximum FXS Loop Length | 3000 ft (Short), 11000 ft (Long) |
Supported Cable Types | Cat 3, Cat 5 |
Backplane Voltage | 12 V |
Current Draw | 5.86 A at 12V |
Power Consumption | 70.32 W |
Unit Weight | 1.98 lb |
Dimensions (H x W x D) | 1.58 in. x 7.44 in. x 7.6 in. |
Operating Temperature Range | 0 °C to 40 °C |
Storage Temperature Range | -40 °C to 70 °C |
SM-X-16FXS/2FXO
Orders typically ship within 1-3 Business days, if you need an item to ship sooner please contact us.
Product Description
The SM-X-16FXS/2FXO module features 16 FXS ports and 2 FXO ports, including 2 FXO failover bypass ports, designed for seamless integration with Cisco 4000 Series ISR platforms, specifically the 4331, 4351, and 4451 models. It supports a variety of signaling formats, including In-Band DTMF and Out-of-Band Pulse signaling for address signaling, and FXS Loop-Start, Ground-Start, and DID Signaling for FXS signaling, accommodating loop resistances up to 600 Ohms for short-loop-length ports and up to 1400 Ohms for long-loop-length ports. The module operates at a voltage of 12 V from the backplane, drawing 5.86 A and consuming 70.32 W of power, with physical dimensions of 1.58 in. height, 7.44 in. width, and 7.6 in. depth, and is designed to function within a temperature range of 0 °C to 40 °C.Key Feature for the SM-X-16FXS/2FXO
- What is the number of FXS and FXO ports available?
The device has 16 FXS ports and 2 FXO ports. - Which ISR platforms are compatible with this hardware?
The hardware is compatible with the 4000 Series ISR platform models 4331, 4351, and 4451. - How are address signaling formats handled?
Address signaling formats include In-Band DTMF and Out-of-Band Pulse (8 to 12 pps). - What types of FXS signaling formats are supported?
Supported FXS signaling formats are FXS Loop-Start, Ground-Start, and DID Signaling. - Can you specify the loop resistance for FXS and DID?
FXS loop resistance can go up to 600 Ohms for short-loop-length ports and up to 1400 Ohms for long-loop-length ports. DID loop resistance supports up to 1800 Ohms. - What are the on-hook voltage and off-hook loop current specifications?
The on-hook voltage is -44 V. The off-hook loop current is 25 mA for short-loop-length ports and 35 mA for long-loop-length ports. - What is the range of ring frequencies supported by this device?
The device supports ring frequencies of 20, 25, 30, and 50 Hz. - What are the FXS loop length capabilities?
FXS loop length capabilities are 3000 ft for short-loop-length ports and 11000 ft for long-loop-length ports. - What types of cables are recommended for use with this hardware?
It is recommended to use Category 3 and Category 5 cables. - What are the power requirements and physical dimensions of the device?
The device requires 12 V from the backplane, drawing 5.86 A on 12V, with a power consumption of 70.32 W. Physical dimensions are 1.98 lb in weight, 1.58 in. in height, 7.44 in. in width, and 7.6 in. in depth.
Product Review
The Cisco SM-X-16FXS/2FXO module offers a significant advantage for networks requiring mixed analog and digital services, supporting 16 FXS and 2 FXO ports, which enables a wide array of voice applications. Compatibility with 4000 Series ISR platforms (4331, 4351, and 4451) ensures seamless integration into existing infrastructures, facilitating easy deployment. However, its operational temperature range from 0°C to 40°C may limit installation in environments with extreme temperatures, potentially requiring additional climate control measures in certain deployments.
Overview
- Ring frequency options of 20, 25, 30, and 50 Hz,
- Support for both Category 3 and Category 5 cables,
- Operation within a voltage of 12 V from the backplane and a current of 5.86 A on 12V, resulting in a power consumption of 70.32 W.
Specifications
Part Number | Cisco SM-X-16FXS/2FXO |
Manufacturer | Cisco |
FXS Port Count | 16 |
FXO Port Count | 2 |
FXO Bypass for Failover | 2 |
Enabled FXS-E Ports | 16 |
Compatible with ISR 4000 Series | 4331, 4351, 4451 |
Supported Address Signaling | In-Band DTMF, Out-of-Band Pulse (8-12 pps) |
FXS Signaling Supported | Loop-Start, Ground-Start, DID |
Resistance for FXS Loop | Up to 600 Ohms (Short), Up to 1400 Ohms (Long) |
DID Loop Resistance | Maximum 1800 Ohms |
Voltage when On-Hook | -44 V |
Loop Current Off-Hook | 25 mA (Short), 35 mA (Long) |
Ring Signal Frequency | 20, 25, 30, 50 Hz |
Maximum FXS Loop Length | 3000 ft (Short), 11000 ft (Long) |
Supported Cable Types | Cat 3, Cat 5 |
Backplane Voltage | 12 V |
Current Draw | 5.86 A at 12V |
Power Consumption | 70.32 W |
Unit Weight | 1.98 lb |
Dimensions (H x W x D) | 1.58 in. x 7.44 in. x 7.6 in. |
Operating Temperature Range | 0 °C to 40 °C |
Storage Temperature Range | -40 °C to 70 °C |