Skip to content

SM-X-16FXS/2FXO

by Cisco
Product Line: Cisco Networking Equipment
Product Type: Router Module
Sold out
Original price $0.00 - Original price $0.00
Original price
$0.00
$0.00 - $0.00
Current price $0.00
Title: Surplus

Orders typically ship within 1-3 Business days, if you need an item to ship sooner please contact us.

Product Description

The SM-X-16FXS/2FXO module features 16 FXS ports and 2 FXO ports, including 2 FXO failover bypass ports, designed for seamless integration with Cisco 4000 Series ISR platforms, specifically the 4331, 4351, and 4451 models. It supports a variety of signaling formats, including In-Band DTMF and Out-of-Band Pulse signaling for address signaling, and FXS Loop-Start, Ground-Start, and DID Signaling for FXS signaling, accommodating loop resistances up to 600 Ohms for short-loop-length ports and up to 1400 Ohms for long-loop-length ports. The module operates at a voltage of 12 V from the backplane, drawing 5.86 A and consuming 70.32 W of power, with physical dimensions of 1.58 in. height, 7.44 in. width, and 7.6 in. depth, and is designed to function within a temperature range of 0 °C to 40 °C.

Key Feature for the SM-X-16FXS/2FXO

  • What is the number of FXS and FXO ports available?
    The device has 16 FXS ports and 2 FXO ports.
  • Which ISR platforms are compatible with this hardware?
    The hardware is compatible with the 4000 Series ISR platform models 4331, 4351, and 4451.
  • How are address signaling formats handled?
    Address signaling formats include In-Band DTMF and Out-of-Band Pulse (8 to 12 pps).
  • What types of FXS signaling formats are supported?
    Supported FXS signaling formats are FXS Loop-Start, Ground-Start, and DID Signaling.
  • Can you specify the loop resistance for FXS and DID?
    FXS loop resistance can go up to 600 Ohms for short-loop-length ports and up to 1400 Ohms for long-loop-length ports. DID loop resistance supports up to 1800 Ohms.
  • What are the on-hook voltage and off-hook loop current specifications?
    The on-hook voltage is -44 V. The off-hook loop current is 25 mA for short-loop-length ports and 35 mA for long-loop-length ports.
  • What is the range of ring frequencies supported by this device?
    The device supports ring frequencies of 20, 25, 30, and 50 Hz.
  • What are the FXS loop length capabilities?
    FXS loop length capabilities are 3000 ft for short-loop-length ports and 11000 ft for long-loop-length ports.
  • What types of cables are recommended for use with this hardware?
    It is recommended to use Category 3 and Category 5 cables.
  • What are the power requirements and physical dimensions of the device?
    The device requires 12 V from the backplane, drawing 5.86 A on 12V, with a power consumption of 70.32 W. Physical dimensions are 1.98 lb in weight, 1.58 in. in height, 7.44 in. in width, and 7.6 in. in depth.

Product Review

The Cisco SM-X-16FXS/2FXO module offers a significant advantage for networks requiring mixed analog and digital services, supporting 16 FXS and 2 FXO ports, which enables a wide array of voice applications. Compatibility with 4000 Series ISR platforms (4331, 4351, and 4451) ensures seamless integration into existing infrastructures, facilitating easy deployment. However, its operational temperature range from 0°C to 40°C may limit installation in environments with extreme temperatures, potentially requiring additional climate control measures in certain deployments.

Overview

The Cisco SM-X-16FXS/2FXO is a service module designed to provide flexible and scalable voice and fax services. It features 16 FXS ports and 2 FXO ports, with an additional 2 FXO failover bypass ports, ensuring continuous communication capabilities. This module is specifically engineered for compatibility with the 4000 Series ISR platform models 4331, 4351, and 4451, offering a seamless integration for businesses looking to expand their voice services. One of the key attributes of the SM-X-16FXS/2FXO is its support for various address and FXS signaling formats. It accommodates In-Band DTMF and Out-of-Band Pulse signaling formats, ranging from 8 to 12 pulses per second. For FXS signaling, it supports Loop-Start, Ground-Start, and DID Signaling, providing flexibility in connecting to different telecommunication interfaces and devices. All 16 FXS ports are enabled with FXS-E, enhancing the module’s capability to handle emergency voice services efficiently. The hardware specifications of the SM-X-16FXS/2FXO are tailored for high-performance voice communication solutions. It features a loop resistance of up to 600 Ohms for short-loop-length ports and up to 1400 Ohms for long-loop-length ports, with DID loop resistance reaching up to 1800 Ohms. The on-hook voltage is set at -44 V, with off-hook loop current specifications of 25 mA for short-loop-length ports and 35 mA for long-loop-length ports. These specifications ensure reliable signal strength and quality over various distances and wiring conditions.
  • Ring frequency options of 20, 25, 30, and 50 Hz,
  • Support for both Category 3 and Category 5 cables,
  • Operation within a voltage of 12 V from the backplane and a current of 5.86 A on 12V, resulting in a power consumption of 70.32 W.
The physical dimensions of the module include a height of 1.58 inches, a width of 7.44 inches, and a depth of 7.6 inches, with a weight of 1.98 lb, making it a compact yet powerful addition to the 4000 Series ISR platforms. It operates efficiently within a temperature range of 0°C to 40°C, with storage temperature tolerances between -40°C and 70°C, ensuring durability and reliability in various operating environments. In summary, the Cisco SM-X-16FXS/2FXO service module stands out for its combination of voice service capabilities, compatibility with Cisco ISR 4000 series, and robust hardware specifications. Its support for multiple signaling formats, along with detailed specifications for loop resistance, voltage, and current, makes it a comprehensive solution for businesses aiming to enhance or expand their voice communication infrastructure.

Specifications

Part NumberCisco SM-X-16FXS/2FXO
ManufacturerCisco
FXS Port Count16
FXO Port Count2
FXO Bypass for Failover2
Enabled FXS-E Ports16
Compatible with ISR 4000 Series4331, 4351, 4451
Supported Address SignalingIn-Band DTMF, Out-of-Band Pulse (8-12 pps)
FXS Signaling SupportedLoop-Start, Ground-Start, DID
Resistance for FXS LoopUp to 600 Ohms (Short), Up to 1400 Ohms (Long)
DID Loop ResistanceMaximum 1800 Ohms
Voltage when On-Hook-44 V
Loop Current Off-Hook25 mA (Short), 35 mA (Long)
Ring Signal Frequency20, 25, 30, 50 Hz
Maximum FXS Loop Length3000 ft (Short), 11000 ft (Long)
Supported Cable TypesCat 3, Cat 5
Backplane Voltage12 V
Current Draw5.86 A at 12V
Power Consumption70.32 W
Unit Weight1.98 lb
Dimensions (H x W x D)1.58 in. x 7.44 in. x 7.6 in.
Operating Temperature Range0 °C to 40 °C
Storage Temperature Range-40 °C to 70 °C