Skip to content

CISCO7613

by Cisco
Product Line: Cisco 7600 Series
Product Type: Chassis
Sold out
Original price $0.00 - Original price $0.00
Original price
$0.00
$0.00 - $0.00
Current price $0.00
Title: Surplus

Orders typically ship within 1-3 Business days, if you need an item to ship sooner please contact us.

Product Description

The CISCO7613 measures 32.7 in. (83 cm) in height, 17.3 in. (43.9 cm) in width, and 18.1 in. (46 cm) in depth, with power requirements ranging from 100 VAC to 240 VAC, and an option for –48 to –60 VDC. It operates reliably within a temperature range of 32°F (0 °C) to 104°F (40°C), with a mean time between failure (MTBF) of 311,778 hours, and can function in environments from 0 to 6500 ft (0 to 2000m) altitude, designed to withstand up to 10,000 ft (3000 m). Compliance with standards including UL 60950, CAN/CSA-C22.2 No. 60950, and EN 60950, along with EMC certifications such as FCC Part 15 Class A and EN55022 Class A, ensures its safety and reliability in various operational environments.

FAQs for the CISCO7613

  • What are the dimensions of the networking hardware?
    • Height: 32.7 in. (83 cm), Width: 17.3 in. (43.9 cm), Depth: 18.1 in. (46 cm).
  • What power requirements does the device have?
    • The device requires 100 VAC (min) to 240 VAC (max) and supports (–48 to –60 VDC).
  • How reliable is the device in terms of MTBF?
    • The device has a Mean Time Between Failure (MTBF) of 311,778 hours.
  • What is the operating temperature range?
    • The operating temperature ranges from 32°F (0 °C) to 104°F (40°C).
  • Can the device be stored in extreme temperatures?
    • Yes, it can be stored in temperatures ranging from –4 °F (–20°C) to 149°F (65°C).
  • What are the humidity requirements for operating and storing the device?
    • Operating humidity: 5% to 90%, noncondensing. Storage humidity: 5% to 95%, noncondensing.
  • Is the device suitable for high-altitude operation?
    • Yes, certified for operation from 0 to 6500 ft (0 to 2000m) and designed for –200 to 10,000 ft (–60 to 3000 m).
  • What regulatory compliance standards does the hardware meet?
    • It meets UL 60950, CAN/CSA-C22.2 No. 60950, EN 60950, IEC 60950, AS/NZS 60950 standards.
  • What are the EMC standards followed by this device?
    • It complies with FCC Part 15 Class A, VCCI Class A, EN55022 Class A, CISPR 22 Class A, and other EMC standards.
  • What are the recommended power requirements for optimal operation?
    • Optimal operation requires between 100 VAC and 240 VAC, or (–48 to –60 VDC).

Product Review

The Cisco CISCO7613 offers a high mean time between failure (MTBF) of 311,778 hours, indicating reliable long-term operation. However, its physical dimensions (height: 32.7 in, width: 17.3 in, depth: 18.1 in) may require significant rack space, potentially limiting its deployment in environments with space constraints. Additionally, while it supports a wide range of power requirements and operational conditions, ensuring compatibility in diverse IT environments, its power consumption might be a consideration for energy-conscious deployments.

Overview

The Cisco CISCO7613 is a networking chassis that offers flexibility, performance, and high availability for service providers and enterprises. With dimensions of 32.7 inches in height, 17.3 inches in width, and 18.1 inches in depth, this chassis is designed to fit in a variety of data center environments. It operates within a power requirement range of 100 VAC minimum to 240 VAC maximum, with an option for –48 to –60 VDC, accommodating diverse electrical infrastructures globally. This product boasts an impressive mean time between failure (MTBF) of 311,778 hours, indicating a reliable performance over extended periods. The operating temperature range is from 32°F (0°C) to 104°F (40°C), and the storage temperature range is from –4°F (–20°C) to 149°F (65°C), ensuring resilience in a wide range of environmental conditions. Furthermore, it operates optimally within a relative humidity range of 5% to 90% non-condensing during operation and 5% to 95% non-condensing during storage. The Cisco CISCO7613 is certified for operation at altitudes from 0 to 6500 ft (0 to 2000m) and has been designed and tested for operation at –200 to 10,000 ft (–60 to 3000 m), offering flexibility for deployment in various geographical locations.
  • Power requirements cater to a broad spectrum, from 100 VAC to 240 VAC, and also include a –48 to –60 VDC option.
  • MTBF of 311,778 hours underscores the product's reliability and durability in demanding operational environments.
  • Compliance with a wide array of regulatory and EMC standards, including UL 60950, FCC Part 15 Class A, and CE marking, ensures safe and reliable operation in diverse markets.
In terms of regulatory compliance and electromagnetic compatibility (EMC), the Cisco CISCO7613 meets stringent standards, including UL 60950 Second Edition, CAN/CSA-C22.2 No. 60950 Second Edition, EN 60950 Second Edition, IEC 60950 Second Edition, and AS/NZS 60950 for safety. For EMC, it complies with FCC Part 15 (CFR 47) Class A, VCCI Class A, EN55022 Class A, CISPR 22 Class A, and several others, ensuring that the product operates within acceptable electromagnetic limits and is compatible with other devices within its environment. Designed to address the needs of high-performance networks, the Cisco CISCO7613 chassis offers a robust solution for both service providers and enterprises looking to deliver high-speed, reliable services. Its comprehensive regulatory compliance, wide range of operating conditions, and high MTBF make it an excellent choice for environments demanding high availability and performance.

Specifications

Item Number CISCO7613 manufactured by Cisco
Dimensions Height: 83 cm, Width: 43.9 cm, Depth: 46 cm
Minimum Power Requirement 100 VAC
Maximum Power Requirement 240 VAC
DC Power Requirement –48 to –60 VDC
MTBF (Mean Time Between Failures) 311,778 hours
Minimum Operating Temperature 0 °C (32 °F)
Maximum Operating Temperature 40 °C (104 °F)
Minimum Storage Temperature –20°C (–4 °F)
Maximum Storage Temperature 65°C (149 °F)
Operating Humidity Range 5% to 90%, non-condensing
Storage Humidity Range 5% to 95%, non-condensing
Operational Altitude Range 0 to 6500 ft (0 to 2000m)
Extended Operational Altitude –200 to 10,000 ft (–60 to 3000 m)
Compliance Standards UL 60950, CAN/CSA-C22.2 No. 60950, EN 60950, IEC 60950, AS/NZS 60950
EMC Standards FCC Part 15 Class A, VCCI Class A, EN55022 Class A, CISPR 22 Class A, CE Marking, AS/NZS 3548 Class A, ETS300 386, EN55024, EN61000-6-1, EN50082-1