RSF Supply is not an authorized distributor. We sell Preowned Surplus and Refurbished products, all warranties are with RSF Supply and not the manufacturer. Firmware or Software is not included.
Overview
- Voltage Input Range of -36 to -72V, with nominal input ratings at -48VDC and 2.0A, accommodating diverse power supply standards.
- Input current specifics of 2.0A at -36 VDC and 1.0A at -72 VDC, with an inrush current peak of 40A, supported by a wire size of 14 AWG and a TYCO PN 206060-1 connector, ensuring efficient and safe power consumption.
- Heat dissipation rated at 75W (369 BTU/hr), optimizing the device's performance by maintaining operational temperatures within safe limits.
Specs
Part Number | Extreme 16151 |
Manufacturer | Extreme |
Height | 1.73 inches / 4.4 cm |
Width | 17.4 inches / 44.1 cm |
Depth | 15.3 inches / 38.9 cm |
Weight | 12.3 lbs / 5.56 kg |
Temperature Operation Range | 0° C to 40° C (32° F to 104° F) |
Humidity During Operation | 10% to 93% RH, non-condensing |
Maximum Operating Elevation | Up to 3,000 meters (9,850 feet) |
Shock Resistance While Operating (Half Sine) | 30m/s2 (3g), 11ms, 60 shocks |
Random Vibration During Operation | 3 – 500 MHz at 1.5g rms |
Temperature During Transport | -40° C to 70° C (-40° F to 158° F) |
Humidity for Storage and Transport | 10% to 95% RH, non-condensing |
Shock Resistance When Packaged (Half Sine) | 180m/s2 (18g), 6ms, 600 shocks |
Sine Vibration When Packaged | 5 – 62 Hz at Velocity 5mm/s, 62-500 Hz at 0.2G |
Random Vibration When Packaged | 5 – 20 Hz at 1.0 ASD w/-3dB/oct. from 20 – 200 Hz |
Minimum Drops from 42 Inches on Sides & Corners | 14 drops (for boxes under 15kg) |
Voltage Input Range | -36V to -72V |
Standard Input Ratings | -48VDC, 2.0A |
Current Input | 2.0A at -36 VDC, 1.0A at -72 VDC |
Peak Inrush Current | 40A maximum |
Input Cable Harness Part Number | Extreme PN 250088 |
Cable Wire Gauge | 14 AWG |
Cable Connector Type | TYCO PN 206060-1 |
Thermal Output | 75W (369 BTU/hr) |
Per-Port Indicators | Status LED for each port including power |
System Status Indicators | LEDs for management, fan, and power status |
16151
Orders typically ship within 1-3 Business days, if you need an item to ship sooner please contact us.
Product Description
The 16151 Extreme has dimensions of 1.73 inches (4.4 cm) in height, 17.4 inches (44.1 cm) in width, and 15.3 inches (38.9 cm) in depth, with a weight of 12.3 lbs (5.56 kg). It operates within a temperature range of 0° C to 40° C (32° F to 104° F) and a humidity range of 10% to 93% relative humidity, non-condensing, at altitudes up to 3,000 meters (9,850 feet). The device is designed for durability, evidenced by its operational shock resistance of 30m/s2 (3g), vibration resistance up to 1.5g rms, and a heat dissipation rate of 75W (369 BTU/hr), complemented by per port status LED and system status LEDs for management, fan, and power.Key Feature for the 16151
- What are the dimensions of the networking device?
The device measures 1.73 inches (4.4 cm) in height, 17.4 inches (44.1 cm) in width, and 15.3 inches (38.9 cm) in depth. - How much does part number 250088 weigh?
It weighs 12.3 lbs (5.56 kg). - What is the operating temperature range for this device?
The operating temperature range is from 0° C to 40° C (32° F to 104° F). - Can part number 206060-1 operate in high humidity environments?
Yes, it can operate in 10% to 93% relative humidity, non-condensing environments. - What are the device's shock and vibration specifications during operation?
Operational shock is specified as 30m/s2 (3g) for 11ms with 60 shocks, and operational random vibration is 3 – 500 MHz @ 1.5g rms. - What input voltage is required for part number 250088?
The required voltage input range is -36 to -72V, with a nominal input rating of -48VDC, 2.0A. - What are the storage and transportation temperature ranges?
The device can be stored and transported within a temperature range of -40° C to 70° C (-40° F to 158° F). - How is part number 206060-1 protected during shipping?
It's protected with packaged shock of 180m/s2 (18g) for 6ms, 600 shocks, and packaged vibration specifications that include sine and random vibrations to ensure safety during transportation. - What type of connectors does the input wire harness use?
The input wire harness uses a connector type TYCO PN 206060-1. - How are the system status and per port status indicated on the device?
The device features per port status LEDs including power status, and system status LEDs for management, fan, and power indicators.
Product Review
The Extreme 16151 offers a compact design with its dimensions, allowing for efficient use of rack space in dense network environments. However, its operating temperature range is limited to 0°C to 40°C, which may not suit all operational climates. Additionally, the device's power requirements and heat dissipation are well-documented, ensuring compatibility and ease of integration into existing infrastructures.
Overview
- Voltage Input Range of -36 to -72V, with nominal input ratings at -48VDC and 2.0A, accommodating diverse power supply standards.
- Input current specifics of 2.0A at -36 VDC and 1.0A at -72 VDC, with an inrush current peak of 40A, supported by a wire size of 14 AWG and a TYCO PN 206060-1 connector, ensuring efficient and safe power consumption.
- Heat dissipation rated at 75W (369 BTU/hr), optimizing the device's performance by maintaining operational temperatures within safe limits.
Specifications
Part Number | Extreme 16151 |
Manufacturer | Extreme |
Height | 1.73 inches / 4.4 cm |
Width | 17.4 inches / 44.1 cm |
Depth | 15.3 inches / 38.9 cm |
Weight | 12.3 lbs / 5.56 kg |
Temperature Operation Range | 0° C to 40° C (32° F to 104° F) |
Humidity During Operation | 10% to 93% RH, non-condensing |
Maximum Operating Elevation | Up to 3,000 meters (9,850 feet) |
Shock Resistance While Operating (Half Sine) | 30m/s2 (3g), 11ms, 60 shocks |
Random Vibration During Operation | 3 – 500 MHz at 1.5g rms |
Temperature During Transport | -40° C to 70° C (-40° F to 158° F) |
Humidity for Storage and Transport | 10% to 95% RH, non-condensing |
Shock Resistance When Packaged (Half Sine) | 180m/s2 (18g), 6ms, 600 shocks |
Sine Vibration When Packaged | 5 – 62 Hz at Velocity 5mm/s, 62-500 Hz at 0.2G |
Random Vibration When Packaged | 5 – 20 Hz at 1.0 ASD w/-3dB/oct. from 20 – 200 Hz |
Minimum Drops from 42 Inches on Sides & Corners | 14 drops (for boxes under 15kg) |
Voltage Input Range | -36V to -72V |
Standard Input Ratings | -48VDC, 2.0A |
Current Input | 2.0A at -36 VDC, 1.0A at -72 VDC |
Peak Inrush Current | 40A maximum |
Input Cable Harness Part Number | Extreme PN 250088 |
Cable Wire Gauge | 14 AWG |
Cable Connector Type | TYCO PN 206060-1 |
Thermal Output | 75W (369 BTU/hr) |
Per-Port Indicators | Status LED for each port including power |
System Status Indicators | LEDs for management, fan, and power status |